How to install a wooden floor using adhesive

This category is listed under Wood flooring articles

Adhesives – How to install a wooden floor using adhesive

Both solid and engineered floors can be installed using wood flooring adhesive, Real Oak Floors recommend the use of Everbuild 650 Wood Flooring Adhesive and Everbuild 750 Quick Drying Flooring Adhesive. There are two main techniques for installing using adhesive which will both be explained. Please remember that solid floors are always recommended to be glued down, not using the floating method.

Floating Floor Method

The floating floor method of fixing the wood flooring is done by gluing the tongues and grooves of the floor together. This creates a new floor which is “floating” over the original floor. Floors can be floated over any solid subfloor and it is the preferred method for laying engineered floors.

It is a good option when the subfloor moisture content is unknown as a damp proof membrane can be used between the floor and subfloor to prevent moisture rising into the new flooring. When floating a floor, an underlay must be used to dampen any echo and extra noise.

This echo is caused by two hard surfaces together which have a space between them. The noise echoes in this void. The underlay is used to prevent any echo as the two hard surfaces will not be touching. There is a wide range of underlays for use when floating the floor – all of which are adequate however one of the best on the market is Silentfloor Gold manufactured by Timbermate. This is a very dense underlay which means there is less sound echo from foot traffic. Generally the more dense an underlay the less noise!

To float the floor:

Lay out the damp proof membrane (if required) ensuring that the edges of the membrane continue up the side of the skirting. Lay out the underlay ensuring all areas of the floor are covered. Any areas left uncovered with the underlay will cause a bounce in the new floor and will be noisier. A PVA adhesive is used to glue the boards together.

Fit the floor by placing two beads of adhesive along the upper and lower sides of the “groove” joint. (It is a common mistake to think that the boards need to be glued along the “tongue” – this will simply push the adhesive too far into the joint and not create a firm bond between the boards.) You must ensure that the beads of glue are constant and not intermittent as this can cause the boards to creak if the joint is not constant.

Leave the joints and glue to dry before walking on the floor. Any PVA glue which has spilled onto the boards can easily be wiped off a lacquered or oiled board, or sanded off an unfinished floor. It must be noted that thermo treated solid oak has less density therefore water based pva will not adhere to the timber as well as normal oak. When using solid thermo treated oak it is best to use another fitting option, however if the boards are engineered this is not a problem as the tongue and grooves are made from the softwood base.

Glue Down Method

The glue down method of fitting a floor consists of using a strong, thick floor specific adhesive applied directly to the subfloor enabling the new floor to stick directly to the original floor. This is a very sturdy method which is the recommended option for solid wood flooring and parquet floors.

To fit a floor using the glue down method you must ensure that the subfloor is dry, level and structurally sound. When fitting onto concrete it is best to prime the area first using a PVA based primer to ensure a good bond to the floor. Any old concrete is recommended to be checked for moisture before the boards are laid. Both engineered flooring and solid flooring can be laid using the glue down method.

To glue the floor down:

Firstly, ensure the subfloor is flat, free from dust and dirt and if necessary has been primed. Working at an area just large enough to complete within 20 minutes, apply the adhesive to the wood floors using a notched trowel ensuring the whole surface has an even amount of glue. Fit the new floor boards ensuring all boards have been pulled tight and have not been moved out of place as other boards have been fitted.

Leave the adhesive to dry for 12 hours and do not walk on the floor until it is fully dry. Unlike the PVA adhesive, the flooring adhesive is very difficult to remove from the surface of the boards so ensure that any spills on the boards are wiped off immediately before the boards have dried.

Other Adhesive based fitting methods:

The are other adhesive based fitting options used to fit flooring:

  1. Adhesive backed flooring underlay. A foam underlay backed with 1 side adhesive. The underlay has a sticky side covered in a plastic film which is peeled back as the floor is laid. Envoy multi, Elastilon and Acoustalay adhesive 300/1000 are all types of adhesive backed underlay.
  2. Slatted Underlay for use with adhesive. This underlay comes with narrow slats cut out – this enables the underlay to be used in conjunction with adhesive as the glue is applied in the cut-outs. The floor benefits from being glued down directly with the added advantage of having an underlay in between. This option is used when the floor is to be glued down directly but the sub floor is not completely flat.

Subscribe to the How to install a wooden floor using adhesive RSS feed.

Interest Free Credit
Win a Holiday!

Member Login

Save details?


from twitter

a brief look at exotic tropical woods - http://eepurl.com/deql

18 June 2010, 11:30 am

todays blogpost looks at underfloor heating http://tinyurl.com/3ycalvm

10 June 2010, 4:09 pm

from our blog

New full trade accounts soon available

Real Oak Floors is proud to announce it is soon to provide full trade accounts for Trade customers. Credit will be subject to status – please fill out the application on our website to go ahead with your new trade account. We will also shortly be updating... more...

13 July 2010, 1:00 pm

Electric underfloor heating, a closer look…

Over the past several years, underfloor heating has become rather popular throughout the UK. With underfloor heating, heat comes from the floor and rises up as opposed to traditional radiators in central heating where the room is heated from the ceiling down. There... more...

10 June 2010, 4:08 pm

Real Oak Floors Affiliate program Our Blog
The Contractors Health and Safety Assessment Scheme The Royal Institue of British Architects

For any queries please email sales@realoakfloors.co.uk Website Designed and Maintained by Foxy Dezine
Real Oak Ltd, 234 Meanwood Road, Off Buslingthrope Green, Leeds, West Yorkshire, LS7 2HG | Tel: 0844 848 6840