Junckers Underfloor Heating Guide

This category is listed under Wood flooring articles

Junckers Underfloor heating guide

General Description

These instructions present general conditions for use of Junckers solid hardwood flooring in structures which include underfloor heating. For detailed information on the individual floor systems and their design with underfloor heating: Clip System Information and Batten System Information and Junckers Glue Down System Information. Reference is also made to Junckers technical information.

To ensure a satisfactory result it is important to study the information on underfloor heating carefully and to comply with the guidelines given.

Conditions for underfloor heating systems and indoor environment

Floor heating systems under wooden floors are normally designed as water-based lowtemperature systems, but in some cases can alternatively be designed as electrical heating systems where cables / mats are cast into the concrete subfloor or laid in the screed.
The underfloor heating system must be of a recognised make and have its own heating circuit and separate temperature regulation, so that the flow temperature is not excessively high. The temperature on the surface of the boards should not exceed 27°C and the system must be adjusted accordingly.

The maximum surface temperature also defines the maximum power output from the floor heating system. An indicative level is a maximum of 100 W/m2. In new, well-insulated buildings this will normally be sufficient, while for renovation projects the power output requirement will be higher, normally making a supplementary heat supply source necessary. The floor heating system must provide even temperature distribution. Where heating pipes or cables are cast in concrete or screed the thickness of the concrete above the pipes must be min. 30 mm. Heating pipes in batten systems and polystyrene boards must always be laid in heat-distribution plates.

Floorboards above floor heating

Wood is a living material. Wood will contract when heated from an underfloor heating system and during the heating season larger board gaps than normal will form between the boards.
The floor temperature under e.g. low bookcases and carpets with good heat insulation properties will be higher than for the rest of the floor, so that larger gaps can be expected in these areas.
Junckers Ship’s Decking is particularly suitable for laying over underfloor heating since the neoprene joint absorbs movement in the floor surface and thereby prevents gaps forming. Junckers wood
Floor laying can begin when the relative humidity (RH) in the building is within the relative humidity range expected in the building when in use. The normal RH of residential buildings is in the range 35-65% RH.

Intermediate layer

In structures with heat-distribution plates floor cardboard, 500 g/m2, is used as an intermediate layer to avoid noise from movement between floorboards and heat-distribution plates.

Flatness of subfloor

Flatness requirement as for other Junckers floor systems, i.e. the subfloor must be flat with maximum deviation of 2mm under a 1.5m straight edge. (UK: 3 mm under a 3m straight edge).

Bearing strength

The load bearing strength of the floor structure must be capable of supporting the actual load.

Terminology

Maximum output [W/m2] The maximum amount of energy, in watts per m2 which radiates from the surface of the floor.
Maximum surface temperature, floorboards [°C] The maximum permitted temperature on the surface of the floorboards.
Flow temperature [°C]
The temperature of the water flowing from the boiler to the heating circuit under the floor.
The flow temperature required to give a floorboard surface temperature of e.g. 27°C depends on the type of floor heating system, the floor structure and the floor covering. The flow temperature will normally lie between 35 and 45ºC. Thermal conductivity, [W/m°K] Expresses the ability of the material to conduct heat.
Thermal resistance [m2°C/W] The thermal resistance of a material is calculated on the basis of the thickness of the material divided by its thermal conductivity. The total thermal conductivity of a structure, e.g. a floor system, comprising boards and intermediate layer, is the sum of the heat resistance in boards and intermediate layer, (S md) Temperature rise down through floorboards, [°C]
Depending on the thermal resistance of the floor covering and the actual power output the temperature will rise down through the floor structure from the surface of the floor covering

Junckers

Information provided by Junckers.

View our range of underfloor heating

Subscribe to the Junckers Underfloor Heating Guide RSS feed.

Interest Free Credit
Win a Holiday!

Member Login

Save details?


from twitter

a brief look at exotic tropical woods - http://eepurl.com/deql

18 June 2010, 11:30 am

todays blogpost looks at underfloor heating http://tinyurl.com/3ycalvm

10 June 2010, 4:09 pm

from our blog

New full trade accounts soon available

Real Oak Floors is proud to announce it is soon to provide full trade accounts for Trade customers. Credit will be subject to status – please fill out the application on our website to go ahead with your new trade account. We will also shortly be updating... more...

13 July 2010, 1:00 pm

Electric underfloor heating, a closer look…

Over the past several years, underfloor heating has become rather popular throughout the UK. With underfloor heating, heat comes from the floor and rises up as opposed to traditional radiators in central heating where the room is heated from the ceiling down. There... more...

10 June 2010, 4:08 pm

Real Oak Floors Affiliate program Our Blog
The Contractors Health and Safety Assessment Scheme The Royal Institue of British Architects

For any queries please email sales@realoakfloors.co.uk Website Designed and Maintained by Foxy Dezine
Real Oak Ltd, 234 Meanwood Road, Off Buslingthrope Green, Leeds, West Yorkshire, LS7 2HG | Tel: 0844 848 6840